故障現(xiàn)象
筆者某次配置了一個AM模塊。出現(xiàn)了一個奇怪的問題。配置好后,撥入時沒有Modem撥號聲。只有電話的聲。并且音指示燈也不亮。當筆者拔下模塊上的電話線時。指示燈亮了。
配置
620#sh run Building configuration... Current configuration : 866 bytes
version 12.2 service timestamps debug uptime service timestamps Jog uptime no service password-encryption
hostname2620 enable secret 5 $1$pUrf$9xGOg.zyxKawi9NljLHHr1 usernameuser password 0 Cisco ip subnet-zero
no ip DOmain-lookup
interface FastEthernet0/0 ip address 136.0.0.254255.255.0.0 duplex auto speed auto
interface Group-Async1 ip unnumbered FastEthernet0/0 encapsulation ppp async default routing async mode interactive peer default ip address pool lab ppp authentication chap group-range 33 48
ip classless no ip http server ip pim bidir-enable
line con 0 password cisco line 33 48 login local modem InOut autocommand ppp transport input all autoselect ppp stopbits 1 flowcontrol hardware line aux0 line vty 0 4 password Cisco login
no scheduler allocate end |
診斷過程 筆者仔細檢查配置文件,發(fā)現(xiàn)缺少ip pool,加上ip local pool lab(start ip addr)(stop ip addr),沒有效果。后來筆者想到撥號采用的都是模擬信號,與接地有很大關(guān)系。沒自動應(yīng)答:多半是接地問題。所以直接把路由器上的接地螺釘,用一根導(dǎo)線接到防靜電地板下面的鐵支柱上,問題解決了。
排除心得
路由器標準接地的方法是在鋪設(shè)電源線的時候放置一根地線,然后路由器的外殼接到地線上去就好?,筆者估計原來負責網(wǎng)絡(luò)系統(tǒng)搭建的廠商采用的電源線忽略了地線,否則也不會出現(xiàn)這樣的問艦。接路由器電源的時候如果有地線,一般不需要我們再接地了。
路由器未接地引起的無法撥號故障解決