.........following with all English text ....c110 ERROR: reading model information status=-3PRoblem Description
I replaced the CPU board on my C110, but now the system is having a hard time identifying the model. Sometimes it id's it as a 9000/777/c110, sometimes as a 9000/800. Typically ss_config is not run on this system, if the io card is replaced it will prompt me to enter the lan station addresses at power up. When the
identification problem occurs I get message:
ERROR: reading model information status=-3, mapper shows can't read model string pdc_model status=-3.
How is this J or C series system hardware problem fixed?
Configuration Info
Operating System - HP-UX
Version -
Hardware System - HP 9000
Series -
Solution
In this case defaulted PDC from the boot console handler, and this cleared the problem.
Alternative KeyWords
status = -3
c160
c180
c200
c240